For photo-flash,lug type,low loss factor and low leakage current.
Operating temperature range: -20-+55 celsius Rated voltage range(V): 330-360 Nominal Capacitance range(uf): 150-2900 Capacitance tolerance(%): -10%-20%(25celsius 120Hz) Leakage current: Kissipation factor(25celsius 120Hz):
CHARGE AND DISCHARGE Charge and discharge at rated voltage at 15-35celsius in every 30 seconds for 5000 times via Xe flash tube with discharge resistance of 0.7-1.0 Capacitance change: Within +-15% of the initial value Leakage current: Not more than200% of the initial specified value Dissipation factor: Not more than 200% of the initial specified value
SHELF LIFE(+55celsius)500 hours Capacitance change: Within +-10% of the initial value Leakage current: Not more than200% of the initial specified value Dissipation factor: Not more than200% of the initial specified value
After test : Rated voltage to be applied for 30 minutes, 24 to 48 hours before measurement. |
|
|
|
|